Repair procedures Removal 1. Remove the left luggage side trim. (Refer to Body - "Luggage Side Trim") 2.
Component Location 1. Engine room relay box 2. ICU Junction block 3. ICM relay box
Description and operation Description The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.
Repair procedures Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.