Hyundai Palisade (LX2): Blower / Climate Control Air Filter

Description and operation

Description
The climate control air filter is located in the blower unit. It eliminates foreign materials and odor. The particle filter performs a role as an odor filter as well as a conventional dust filter to ensure comfortable interior environment.

Repair procedures

Replacement
Hyundai Palisade. Repair procedures   
•
When removing with a flat-tip screwdriver or remover, wrap protective tape around the tools to prevent damage to components.
•
Put on gloves to prevent hand injuries.
1.
Remove the stopper (B) from the glove box (A).

Hyundai Palisade. Repair procedures

2.
Remove the air damper (A) from the glove box (B).

Hyundai Palisade. Repair procedures

3.
Remove the filter cover (A) by pressing the knob.

Hyundai Palisade. Repair procedures

4.
Replace the air filter (A) with a new one according to the direction of air filter.

Hyundai Palisade. Repair procedures

5.
Install in the reverse order of removal.
Hyundai Palisade. Repair procedures   
•
To remove the filter easily, press the right side inward then pull out the filter.
•
In case of driving in an air-polluted area or rugged terrain, check and replace the air filter as frequently as possible.

    Repair procedures Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and measure the voltage of the blower motor.

    Description and operation Description The intake actuator is located at the blower unit. It regulates the intake door by a signal from the control unit.

    Other information:

    Hyundai Palisade (LX2) 2020-2025 Service Manual: Temperature Control Actuator

    Description and operation Description The heater unit includes mode control actuator and temperature control actuator. The temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows.

    Hyundai Palisade (LX2) 2020-2025 Service Manual: Surround View Monitor (SVM) Unit

    Components and components location Components No Connector A 1 ACC 2 LED 3 EXT Ground 4 Y Shield 5 - 6 C-CAN Low 7